Stop corrosion.

Floating dry dock

Floating dry dock - Corrosion Protection with nC Corrosion Passivator Fluid

Protect ballast tanks without downtime

Protect the structural integrity of your floating dry docks, pontoons, and internal ballast tanks against active saltwater corrosion. nC Corrosion Passivator Fluid provides long-term protection directly over wet, rusted steel, eliminating scaffolding, grit blasting, and operational downtime.

Downloads

Case study – Floating Dry Dock

Case study – Floating Dry Dock

The operational challenge

Conventional coatings fail in active shipyard environments due to major operational bottlenecks:

  • Scaffolding constraints: Erecting staging inside narrow, high-vertical wing towers is labor-intensive, costly, and nearly impossible in complex frame geometries.

  • Grit blasting hazards & waste: Traditional abrasive blasting in confined spaces is labour intensive, time consuming, and creates heavy grit waste removal burdens.

  • Surface preparation limits: Standard coatings demand dry, sandblasted steel before application. A condition virtually impossible to maintain in damp ballast tanks during active operations.

Floating-Dry-Dock-16 Scaffolding
Challenge Traditional coatings nC Corrosion Passivator Fluid
Surface tolerance Requires clean, dry, sandblasted substrate.

Applies directly onto wet, rusted steel with no blasting required.

Access & staging Requires extensive scaffolding inside wing towers. Floating application covers entire tanks without scaffolding.
Asset availability Downtime during preparation, application, and cure. Application in-service during routine docking schedules.
Environmental impact Grit waste and solvent emissions. Non-petroleum, VOC-free formula eliminates toxic grit waste and hazardous solvents.

nC Corrosion Passivator Fluid

Applied directly over damp, rusted steel via float or spray, it stops active ballast tank corrosion during daily operations.

nC Corrosion Passivator Fluid - Floating dry dock

Application method

Floating-Dry-Dock Detailed image rust

Preparation of the metal surface

The application of nC Corrosion Passivator Fluid requires no grit blasting or mechanical surface preparation, bonding directly to wet, rusted steel. Heating or drying of the surface is not necessary.

nC Corrosion Passivator Fluid - Floating dry dock

Application by airless spray

The application process combines targeted airless spraying for accessible lower zones and overhead framing with a floating technique using either fresh or salt water. The calculated consumption for airless spray application is 5 to 7 m² per liter.

Application by floating

nC Corrosion Passivator Fluid floats on water. After crew members spray initial structures, they pour the calculated Fluid volume onto the water inside the ballast tank, and allow routine ballasting cycles to distribute the product to the tank surface. The calculated consumption for floating application is 1 liter per 1 m³

nC Corrosion Passivator FLuid Application during operation

No down time

Application can be performed entirely in-service during routine docking schedules, preserving structural integrity without sacrificing dry dock availability.

Floating Dry Dock after application with nC Corrosion Passivator Fluid

Post-application visual inspection

Following deballasting, the steel surface reacts with the fluid, turning into a distinct anthracite-colored protective layer.

Proven track record since 2021: Bridge pontoon

Since 2021, Shipyard Reimerswaal has used nC Corrosion Passivator Fluid and the spray-and-float method to protect internal bridge pontoon structures. Successful passivation turned active rust (bright orange) into a stable dark anthracite layer. After 4.5 years, the pontoon remains well-protected, with only minor spots needing touch-ups. Following this proven performance, the shipyard has chosen the same treatment for their floating dry dock.

Bridge pontoon - nC Corrosion Passivator Fluid - Inspection after 4.5 years.Bridge pontoon - nC Corrosion Passivator Fluid - Inspection after 4.5 years.Bridge pontoon - nC Corrosion Passivator Fluid - Inspection after 4.5 years.

Before and after application with nC Corrosion Passivator Fluid

Floating dry dock - Corrosion Protection with nC Corrosion Passivator FluidFloating dry dock - After application of nC Corrosion Passivator Fluid

Downloads

Case study – Floating Dry Dock

Case study – Floating Dry Dock

Get in touch

Contact our team with any technical questions or to request a quote.